Simple


Please follow the next guidelines for troubleshooting device pairing problems:

- The red color LED is blinking continuously after power up?

- The frequency of blinking LED is changing if you press the bonding button?


If the response are YES,  then the sensor is not bounded.

- Do you use  RF channel 52 in Coordinator?

- Do you use LP mode on Coordinator?

- Did you received positive response from IQRF IDE at bonding process?

If you are not familiar with bonding process I recommend to check this video from 3:00. https://www.youtube.com/watch?v=ZSlw_qBQu4E


Advanced


If you have not been able to solve the issue yet, then please follow the next guidelines:


You can create CATS from any DCTR-72DA module in IQRF IDE with Tools -> CATS Service tools -> Control menu point in IQRF IDE.  Click on Create CATS button.

You can connect to device with Connect button on DPA Service Mode Tab.

Finalizing the connection procedure you have to power-off and on the sensor device.


- Do you use Coordinator with IQRF OS 4.02D?

- Do you use DPA version 3.02? 

- Do you use Coordinator with RF channel 52 in Coordinator? 

- Do you use LP mode in the Coordinator? 

- Did you received positive response from Coordinator in the IQRF IDE at bonding process?